YR2Q
DIN RAIL MOUNT
8R2Q
8 PIN PLUG-IN
11R2Q
11 PIN PLUG-IN
Mode of operation:
Timing commences with the closure of S (supply on). At the end of timing the star relay is energised. After a dwell of 100mS the delta relay is energised. The contact states are maintained until removal of the supply.Function [2Q],

Note: Din-rail
version contacts are:
Star..1 x N/C Delta...1 x N/O
Features:
| Star time adjustable. | |
| LED operation indicator. | |
| 5 Ampere rated contacts. | |
| Only 24mm wide case. | |
| 100mS dwell time. |
Voltages:
230Vac
110Vac
48Vac/dc
24Vac/dc
12Vdc
Timing Ranges:
0.1- 1s 0.1- 3s 0.06- 6s
0.1- 10s 0.2- 20s 0.3- 30s 0.6-
60s 1- 100s 3- 300s 0.03-
3m 0.1- 10m 5- 10m 0.2-
20m 0.3- 30m 0.6-
60m 1- 100m 2-
200m 3- 300m
Specification:
| Supply tolerance. | 0.85 to 1.15 Un |
| Frequency | 50 - 60Hz |
| Power consumption | 11VA at 220Vac |
| Output. | Separate isolated contacts for Star and Delta. |
| Change-over Dwell time. | 100mS (30mS option) |
| Contact material | AgNi |
| Maximum loading | 5A |
| Maximum switching voltage | 250Vac or 30Vdc |
| Relay Maximum power rating | 960VA or 120W |
| Mechanical life of relay. | 2x107 operations |
| Electrical life of relay. | 5x104 operations at full load. |
| Setting accuracy | 0 to +30% |
| Repeat accuracy at a constant ambient. | ± 0.5% |
| Repeat
accuracy within temperature specification of VDE0435 |
± 3% |
| Reset
time: After
timing. During timing |
100mS 100mS |
| Operating and storage temperature. | -20 to +60oC |
| Connection | Screw terminal or plug in. |
| Weight. | 80g |
Ordering Example:
YR2Q 10S 230V
Connection: